  1. Carroll Meynell 2250/2 Transformer Twin Outlet Rating 2.25kVA Continuous 1.125kVA

    SKU: PTDC/M22502

    List Price:  

    £149.00

    Our Price:  

    £68.65

    Inc VAT:  

    £82.38

    Carroll & Meynell transformers are primarily for use when using portable electric tools on outdoor sites.

    They are manufactured to BS EN 61558 and have thermal overload protection and with BS EN 60309 output sockets as standard. They have a glass reinforced polyester case and input flex and 13 amp plug. The 5kVA model is without a fitted plug, max input current 23 amp.

    The Carroll & Meynell transformers are completely encapsulated for extra weatherproofing.

    These transformers are rated for intermittent operation at their maximum listed power capability for a duty cycle of 25%. i.e. 5 minutes ON 15 minutes OFF. They may be used in a continuous operation mode at a rating of 50% of their maximum capability. E.g. a 3.3kVA unit may be operated continuously at 1.65kVA.

    Tool Rating 2.25kVA.
    Output Sockets. 2 x 16amp.

    Transformer Specifications

    Input 240 volts 50Hz single phase. Complete with 2 metres of 3-core flexible cable to BS6500 for connection to mains supply and a 13 amp plug.

    Output 110 volts. Centre tapped and earth screen between primary and secondary windings which is bonded to the centre tap of the secondary winding, the earth pin on each output socket and earth core of the mains input plugs and sockets.

    BS4343 flush type sockets with spring flap covers fitted as standard. Units are protected by suitably rated thermal overload cut-outs.

    Portable Tool Transformer - Safety Instructions
    1. The transformer will get warm in normal use, make sure that the heat will not damage any floor covering that it is standing on. It is not advisable to place the transformer onto carpet, vinyl floor covering, etc., and use at continuous rating for any length of time.

    4. Although the transformer may be of insulated construction, it is not double insulated (class 2) and the earth pin of the output socket must be connected to the centre point of the secondary winding and to the transformer incoming earth.

    2. The transformer may be fitted with an over temperature cut-out switch, in the event of this operating, let the unit cool down then reset the cut-out switch before using again.

    5. Power tool transformers must not be tested as class 2 appliances on portable appliance testers, flash test only at 1.5 Kv.

    3. Check the transformer power rating against the power rating of the tool you are going to use. The transformer can supply portable tools in normal use up to the rating shown on the transformer and consultation with the above table. Care should be taken when using the transformer to supply constant loads, i.e. floodlights, wallpaper strippers etc. The transformer can only supply about half of its rated power to continuous load like this.

    6. Power tool transformers have an inherent high inrush current, in the event of the fuse blowing on switch, check that the fuse in the input plug is suitably rated and is of the anti surge type. Miniature circuit breakers protecting the sockets should have a type 4 tripping characteristic.

    PTDC/M22502

    Learn More
  2. Carroll Meynell 750/1 Transformer Single Outlet Rating 750VA Continuous 375VA

    SKU: PTDC/M7501

    List Price:  

    £117.66

    Our Price:  

    £63.20

    Inc VAT:  

    £75.84

    Carroll & Meynell transformers are primarily for use when using portable electric tools on outdoor sites.

    They are manufactured to BS EN 61558 and have thermal overload protection and with BS EN 60309 output sockets as standard. They have a glass reinforced polyester case and input flex and 13 amp plug. The 5kVA model is without a fitted plug, max input current 23 amp.

    The Carroll & Meynell transformers are completely encapsulated for extra weatherproofing.

    These transformers are rated for intermittent operation at their maximum listed power capability for a duty cycle of 25%. i.e. 5 minutes ON 15 minutes OFF. They may be used in a continuous operation mode at a rating of 50% of their maximum capability. E.g. a 3.3kVA unit may be operated continuously at 1.65kVA.

    Tool Rating 750VA.
    Output Sockets. 1 x 16amp.

    Transformer Specifications

    Input 240 volts 50Hz single phase. Complete with 2 metres of 3-core flexible cable to BS6500 for connection to mains supply and a 13 amp plug.

    Output 110 volts. Centre tapped and earth screen between primary and secondary windings which is bonded to the centre tap of the secondary winding, the earth pin on each output socket and earth core of the mains input plugs and sockets.

    BS EN60309 flush type sockets with spring flap covers fitted as standard. Units are protected by suitably rated thermal overload cut-outs.

    Portable Tool Transformer - Safety Instructions
    1. The transformer will get warm in normal use, make sure that the heat will not damage any floor covering that it is standing on. It is not advisable to place the transformer onto carpet, vinyl floor covering, etc., and use at continuous rating for any length of time.

    4. Although the transformer may be of insulated construction, it is not double insulated (class 2) and the earth pin of the output socket must be connected to the centre point of the secondary winding and to the transformer incoming earth.

    2. The transformer may be fitted with an over temperature cut-out switch, in the event of this operating, let the unit cool down then reset the cut-out switch before using again.

    5. Power tool transformers must not be tested as class 2 appliances on portable appliance testers, flash test only at 1.5 Kv.

    3. Check the transformer power rating against the power rating of the tool you are going to use. The transformer can supply portable tools in normal use up to the rating shown on the transformer and consultation with the above table. Care should be taken when using the transformer to supply constant loads, i.e. floodlights, wallpaper strippers etc. The transformer can only supply about half of its rated power to continuous load like this.

    6. Power tool transformers have an inherent high inrush current, in the event of the fuse blowing on switch, check that the fuse in the input plug is suitably rated and is of the anti surge type. Miniature circuit breakers protecting the sockets should have a type 4 tripping characteristic.

    PTDC/M7501

    Learn More
  3. Carroll Meynell Transformer Twin Outlet Range

    SKU: PTDGRPCM10002

    From:  

    £63.20

    Inc VAT:  

    £75.84

    Carroll & Meynell transformers are primarily for use when using portable electric tools on outdoor sites.

    They are manufactured to BS EN 61558 and have thermal overload protection and with BS EN 60309 output sockets as standard. They have a glass reinforced polyester case and input flex and 13 amp plug. The 5kVA model is without a fitted plug, max input current 23 amp.

    The Carroll & Meynell transformers are completely encapsulated for extra weatherproofing.

    These transformers are rated for intermittent operation at their maximum listed power capability for a duty cycle of 25%. i.e. 5 minutes ON 15 minutes OFF. They may be used in a continuous operation mode at a rating of 50% of their maximum capability. E.g. a 3.3kVA unit may be operated continuously at 1.65kVA.

    PTDGRPCM10002

    Learn More
  4. Carroll Meynell 1000/2 Transformer Twin Outlet Rating 1kVA Continuous 500VA

    SKU: PTDC/M10002

    List Price:  

    £123.62

    Our Price:  

    £64.53

    Inc VAT:  

    £77.44

    Carroll & Meynell transformers are primarily for use when using portable electric tools on outdoor sites.

    They are manufactured to BS EN 61558 and have thermal overload protection and with BS EN 60309 output sockets as standard. They have a glass reinforced polyester case and input flex and 13 amp plug. The 5kVA model is without a fitted plug, max input current 23 amp.

    The Carroll & Meynell transformers are completely encapsulated for extra weatherproofing.

    These transformers are rated for intermittent operation at their maximum listed power capability for a duty cycle of 25%. i.e. 5 minutes ON 15 minutes OFF. They may be used in a continuous operation mode at a rating of 50% of their maximum capability. E.g. a 3.3kVA unit may be operated continuously at 1.65kVA.

    Tool Rating 1kVA.
    Output Sockets. 2 x 16amp.

    Transformer Specifications

    Input 240 volts 50Hz single phase. Complete with 2 metres of 3-core flexible cable to BS6500 for connection to mains supply and a 13 amp plug.

    Output 110 volts. Centre tapped and earth screen between primary and secondary windings which is bonded to the centre tap of the secondary winding, the earth pin on each output socket and earth core of the mains input plugs and sockets.

    BS4343 flush type sockets with spring flap covers fitted as standard. Units are protected by suitably rated thermal overload cut-outs.

    Portable Tool Transformer - Safety Instructions
    1. The transformer will get warm in normal use, make sure that the heat will not damage any floor covering that it is standing on. It is not advisable to place the transformer onto carpet, vinyl floor covering, etc., and use at continuous rating for any length of time.

    4. Although the transformer may be of insulated construction, it is not double insulated (class 2) and the earth pin of the output socket must be connected to the centre point of the secondary winding and to the transformer incoming earth.

    2. The transformer may be fitted with an over temperature cut-out switch, in the event of this operating, let the unit cool down then reset the cut-out switch before using again.

    5. Power tool transformers must not be tested as class 2 appliances on portable appliance testers, flash test only at 1.5 Kv.

    3. Check the transformer power rating against the power rating of the tool you are going to use. The transformer can supply portable tools in normal use up to the rating shown on the transformer and consultation with the above table. Care should be taken when using the transformer to supply constant loads, i.e. floodlights, wallpaper strippers etc. The transformer can only supply about half of its rated power to continuous load like this.

    6. Power tool transformers have an inherent high inrush current, in the event of the fuse blowing on switch, check that the fuse in the input plug is suitably rated and is of the anti surge type. Miniature circuit breakers protecting the sockets should have a type 4 tripping characteristic.

    PTDC/M10002

    Learn More
  5. Carroll Meynell 10K16 Transformer Six Outlet 10kVA 230V

    SKU: PTDC/M10K16

    List Price:  

    £674.16

    Our Price:  

    £398.35

    Inc VAT:  

    £478.02

    Transformer for operation from single phase 230V mains supplies providing 110V Center Tapped Earth (CTE) output for the operation of portable tools, lighting and other construction site equipment.

    It is designed to provide power of 10kVA through a number of output socket options.

    The unit has 4 x 16A sockets and 2 x 32A sockets.

    - heavy-duty sheet steel enclosure to IP23
    - Manufactured generally to BS4363
    - MCB overload protection for both the input and outputs
    - Output sockets to BS EN 60309 / IEC 60309 (Previously BS4343)
    - M5 Stud input terminals to accept your cabling

    PTDC/M10K16

    Learn More
  6. Carroll Meynell 10K36 Transformer Six Outlet 10kVA 400V

    SKU: PTDC/M10K36

    List Price:  

    £835.70

    Our Price:  

    £498.34

    Inc VAT:  

    £598.01

    Transformer for operation from three phase 400V supply providing 110V Center Tapped Earth (CTE) output for the operation of portable tools, lighting and other construction site equipment.

    It is designed to provide power of 10kVA through a number of output socket options.

    The unit has 4 x 16A sockets and 2 x 32A sockets.

    - Heavy-duty sheet steel enclosure to IP23
    - Manufactured generally to BS 4363
    - MCB overload protection for both the input and outputs
    - Output sockets to BS EN 60309 / IEC 60309 (Previously BS 4343)
    - M5 Stud input terminals to accept your cabling

    PTDC/M10K36

    Learn More
  7. Carroll Meynell 5003/3 Transformer Triple Outlet Rating 5kVA Continuous 2.5kVA

    SKU: PTDC/M5003

    List Price:  

    £215.09

    Our Price:  

    £146.81

    Inc VAT:  

    £176.17

    Carroll & Meynell transformers are primarily for use when using portable electric tools on outdoor sites.

    They are manufactured to BS EN 61558 and have thermal overload protection and with BS EN 60309 output sockets as standard. They have a glass reinforced polyester case and input flex and 13 amp plug. The 5kVA model is without a fitted plug, max input current 23 amp.

    The Carroll & Meynell transformers are completely encapsulated for extra weatherproofing.

    These transformers are rated for intermittent operation at their maximum listed power capability for a duty cycle of 25%. i.e. 5 minutes ON 15 minutes OFF. They may be used in a continuous operation mode at a rating of 50% of their maximum capability. E.g. a 3.3kVA unit may be operated continuously at 1.65kVA.

    2 x 16 amp outlets, 1 x 32 amp outlet.

    Intermittent transformer.

    This item shipped without an input plug. Maximum input current 23A.

    Portable Tool Transformer - Safety Instructions
    1. The transformer will get warm in normal use, make sure that the heat will not damage any floor covering that it is standing on. It is not advisable to place the transformer onto carpet, vinyl floor covering, etc., and use at continuous rating for any length of time.

    4. Although the transformer may be of insulated construction, it is not double insulated (class 2) and the earth pin of the output socket must be connected to the centre point of the secondary winding and to the transformer incoming earth.

    2. The transformer may be fitted with an over temperature cut-out switch, in the event of this operating, let the unit cool down then reset the cut-out switch before using again.

    5. Power tool transformers must not be tested as class 2 appliances on portable appliance testers, flash test only at 1.5kVA.

    3. Check the transformer power rating against the power rating of the tool you are going to use. The transformer can supply portable tools in normal use up to the rating shown on the transformer and consultation with the above table. Care should be taken when using the transformer to supply constant loads, i.e. floodlights, wallpaper strippers etc. The transformer can only supply about half of its rated power to continuous load like this.

    6. Power tool transformers have an inherent high inrush current, in the event of the fuse blowing on switch, check that the fuse in the input plug is suitably rated and is of the anti-surge type. Miniature circuit breakers protecting the sockets should have a type 4 tripping characteristic.

    PTDC/M5003

    Learn More
No more product

Power Tool Accessories and Spares


Whether you are a weekend DIY enthusiast or a professional builder, you recognise the value of having a good supply of multi tool accessories. Power Tools Direct carries a wide range of accessories from leading brands such as Black and Decker, Bosch, Irwin and Faithfull. Your tool kit needs to be fully equipped with top quality, heavy duty drill bits, chucks, saw blades, sanding discs or belts - everything you need to ensure that your tools are operating to the highest standard. Its also prudent to keep power tool spares and replacements to hand - you never know when something will break mid-project.


When youre looking for a trusted brand of multi tool accessories and power tool spares, you wont find better value for money than at Power Tools Direct. Most of our products are shipped directly from the manufacturer, ensuring that you receive your power tool accessories at trade cost, significantly lower than you would normally pay. Dont forget that shipping is free on orders of over a certain amount!